✅ This Agilent 8890 GC System with 7650A Autosampler and FID Detector has been fully tested and refurbished at our in-house testing laboratory.
The Agilent 8890 GC System with 7650A Autosampler and Flame Ionization Detector (FID) is a modern gas chromatography platform designed for reliable, high-throughput analysis of volatile and semi-volatile organic compounds. The FID detector is highly sensitive to hydrocarbons and organic compounds, offering a wide linear dynamic range and stable response, making it ideal for quantitative analysis of compounds such as petroleum hydrocarbons, solvents, alcohols, and VOCs. This configuration is widely used in environmental testing, petrochemical analysis, food and flavor profiling, pharmaceutical QC, and industrial chemical analysis, supporting workflows aligned with EPA, ASTM, ISO, and internal SOP-based methods where GC-FID detection is specified. Known for its robustness, automation, and consistent performance, the Agilent 8890 GC with 7650A Autosampler and FID is a dependable solution for laboratories requiring accurate and high-throughput gas chromatographic analysis.
At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent 8890 GC System with 7650A Autosampler and FID Detector has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.
Included with Agilent 8890 GC System with 7650A Autosampler and FID Detector
Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.
Insights by AMPTIUS | AMP Tech Instruments
Agilent 8890 GC System with FID Detector and 7650A Autosampler: Applications in Petrochemical, Food, and Pharmaceutical Laboratories
The Agilent 8890 GC System with a Flame Ionization Detector (FID) and Agilent 7650A Automatic Liquid Sampler is a high-performance gas chromatography platform widely used in petrochemical, environmental, food and beverage, pharmaceutical, chemical manufacturing, biofuel, cannabis, and industrial quality control laboratories. Common laboratory applications include hydrocarbon profiling, residual solvent analysis, fatty acid methyl ester (FAME) analysis, biodiesel characterization, volatile organic compound (VOC) testing, alcohol and fermentation analysis, flavor and fragrance testing, fuel quality assessment, and chemical purity determination. The FID provides exceptional sensitivity, wide linear dynamic range, and highly reproducible quantitation for organic compounds, making it one of the most widely used detectors for routine GC analysis. The 7650A Autosampler enhances laboratory productivity by delivering precise, reproducible automated injections that reduce operator variability and support high-throughput testing environments. Petrochemical laboratories frequently utilize this configuration for ASTM fuel testing methods, while food and beverage laboratories rely on it for flavor compound analysis and fermentation monitoring. Pharmaceutical and chemical manufacturing facilities benefit from reliable quantitation of solvents, intermediates, and finished products. Combined with intelligent system diagnostics, advanced electronic pneumatics control, robust chromatographic performance, and dependable automation, the Agilent 8890 GC with FID and 7650A Autosampler provides an excellent solution for routine quality control, regulatory compliance, and research applications requiring accurate and reproducible gas chromatographic analysis.
Agilent 8890 GC with FID and 7650A Autosampler: Refurbished System Benefits and Pricing
Certified refurbished systems typically range from $34,500 to $37,000, providing substantial savings compared to new systems, which generally cost between $60,000 and $75,000 depending on configuration, software, and accessory options. In addition to the initial acquisition cost, laboratories should consider ongoing operational expenses such as carrier gas consumption, detector gases (hydrogen, air, or nitrogen), septa and inlet liners, GC columns, autosampler consumables, calibration standards, preventive maintenance, software support, and compliance-related qualification services. Long-term ownership costs are manageable due to the 8890 GC’s robust design, low-maintenance components, and widely available replacement parts. Purchasing a certified refurbished Agilent 8890 GC with FID and 7650A Autosampler allows laboratories to reduce upfront investment while benefiting from high sensitivity, wide dynamic range, reproducible automated injections, dependable chromatographic performance, and reliable analytical results for hydrocarbon profiling, VOC testing, fuel analysis, residual solvent quantitation, and other routine or regulatory GC workflows.
EPA Method 8015D: Nonhalogenated Organics with Agilent 8890 GC with FID and 7650A Autosampler
The Agilent 8890 GC System with a Flame Ionization Detector (FID) and Agilent 7650A Automatic Liquid Sampler provides a highly effective platform for EPA Method 8015D, which is used for the determination of nonhalogenated volatile and semivolatile organic compounds in environmental samples. The 8890 GC delivers exceptional chromatographic separation of complex hydrocarbon mixtures, including gasoline range organics (GRO), diesel range organics (DRO), total petroleum hydrocarbons (TPH), waste oils, and other petroleum-derived contaminants commonly encountered in soil, groundwater, wastewater, and remediation project samples. The FID offers outstanding sensitivity, excellent quantitative accuracy, and a wide linear dynamic range for organic compounds, enabling reliable quantitation across a broad concentration range while maintaining analytical robustness. The integrated 7650A Autosampler provides precise and reproducible automated sample introduction, supporting consistent results, improved laboratory productivity, and high-throughput analytical workflows. Environmental laboratories benefit from dependable retention time reproducibility, strong quantitative performance, and efficient batch processing capabilities that support regulatory compliance, site characterization, remediation monitoring, and environmental risk assessment projects. Combined with advanced GC technology, reliable FID detection, and automated sample handling, the Agilent 8890 GC with FID and 7650A Autosampler provides a powerful solution for EPA Method 8015D nonhalogenated organic analysis and environmental testing applications.