Hot

Agilent 8890 GC System with FID and 7650A ALS Autosampler

Fully Tested and Refurbished

Warranty: Includes a 180-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Agilent 8890 GC with FID and 7650A ALS Autosampler has been fully tested and refurbished at our in-house testing laboratory.

The Agilent 8890 GC System with 7650A Autosampler and Flame Ionization Detector (FID) is a modern gas chromatography platform designed for reliable, high-throughput analysis of volatile and semi-volatile organic compounds. The FID detector is highly sensitive to hydrocarbons and organic compounds, offering a wide linear dynamic range and stable response, making it ideal for quantitative analysis of compounds such as petroleum hydrocarbons, solvents, alcohols, and VOCs. This configuration is widely used in environmental testing, petrochemical analysis, food and flavor profiling, pharmaceutical QC, and industrial chemical analysis, supporting workflows aligned with EPA, ASTM, ISO, and internal SOP-based methods where GC-FID detection is specified. Known for its robustness, automation, and consistent performance, the Agilent 8890 GC with 7650A Autosampler and FID is a dependable solution for laboratories requiring accurate and high-throughput gas chromatographic analysis.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent 8890 GC System with FID and 7650A ALS Autosampler has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Agilent 8890 GC System with 7650A Autosampler and FID Detector

  • Agilent 8890 Network GC Gas Chromatograph
  • Agilent 7650 50-Position Autosampler Injector Tower
  • S/SL Inlet
  • FID Detector
  • Computer Workstation with Software
  • All Required Power and Communication Cables

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

High-Performance Gas Chromatography for Routine and Advanced Chemical Analysis

If your laboratory is bottlenecked by manual injection errors or unexpected instrument downtime during organic screening, the Agilent 8890 GC system equipped with a Flame Ionization Detector (FID) and a 7650A autosampler delivers the ultimate intelligent, automated solution. Featuring smart diagnostic tools and automatic system monitoring, this high-performance gas chromatograph utilizes advanced Electronic Pneumatic Control (EPC) to guarantee flawless peak resolution and highly reproducible retention times. The integrated Flame Ionization Detector provides ultra-sensitive hydrocarbon detection over a wide linear dynamic range of 10⁷, while the Agilent 7650A Automatic Liquid Sampler (ALS) eliminates operator injection variability during high-throughput, automated sequences. It is a premier, robust workhorse for environmental labs tracking volatile organic compounds (VOCs), petrochemical processing facilities, and pharmaceutical operations running critical residual solvent testing.


Agilent 8890 GC with FID and 7650A Autosampler: Refurbished System Benefits and Pricing

Certified refurbished systems typically range from $34,500 to $37,000, providing substantial savings compared to new systems, which generally cost between $60,000 and $75,000 depending on configuration, software, and accessory options. In addition to the initial acquisition cost, laboratories should consider ongoing operational expenses such as carrier gas consumption, detector gases (hydrogen, air, or nitrogen), septa and inlet liners, GC columns, autosampler consumables, calibration standards, preventive maintenance, software support, and compliance-related qualification services. Long-term ownership costs are manageable due to the 8890 GC’s robust design, low-maintenance components, and widely available replacement parts. Purchasing a certified refurbished Agilent 8890 GC with FID and 7650A Autosampler allows laboratories to reduce upfront investment while benefiting from high sensitivity, wide dynamic range, reproducible automated injections, dependable chromatographic performance, and reliable analytical results for hydrocarbon profiling, VOC testing, fuel analysis, residual solvent quantitation, and other routine or regulatory GC workflows.


EPA Method 8015D: Nonhalogenated Organics using the Agilent 8890 Gas Chromatograph with FID and 7650A ALS Autosampler

The Agilent 8890 GC System with a Flame Ionization Detector (FID) and Agilent 7650A Automatic Liquid Sampler provides a highly effective platform for EPA Method 8015D, which is used for the determination of nonhalogenated volatile and semivolatile organic compounds in environmental samples. The 8890 GC delivers exceptional chromatographic separation of complex hydrocarbon mixtures, including gasoline range organics (GRO), diesel range organics (DRO), total petroleum hydrocarbons (TPH), waste oils, and other petroleum-derived contaminants commonly encountered in soil, groundwater, wastewater, and remediation project samples. The FID offers outstanding sensitivity, excellent quantitative accuracy, and a wide linear dynamic range for organic compounds, enabling reliable quantitation across a broad concentration range while maintaining analytical robustness. The integrated 7650A Autosampler provides precise and reproducible automated sample introduction, supporting consistent results, improved laboratory productivity, and high-throughput analytical workflows. Environmental laboratories benefit from dependable retention time reproducibility, strong quantitative performance, and efficient batch processing capabilities that support regulatory compliance, site characterization, remediation monitoring, and environmental risk assessment projects. Combined with advanced GC technology, reliable FID detection, and automated sample handling, the Agilent 8890 GC with FID and 7650A Autosampler provides a powerful solution for EPA Method 8015D nonhalogenated organic analysis and environmental testing applications.


AMP Tech Analytical Solutions for Academic Research and Grant-Funded Laboratories

At AMPTIUS | AMP Tech Instruments, we support the advancement of scientific education and innovation by providing cost-effective analytical instruments tailored to the unique budget constraints of the academic sector. Every pre-owned system in our inventory is independently evaluated and fully verified within our in-house testing laboratory, making our AMP Tech Certified equipment an ideal choice for university chemistry departments, core facilities, and researchers optimizing limited grant funding. Because academic applications vary heavily from undergraduate teaching labs to complex graduate research, we precisely document each unique listing to ensure the specific components align with your educational goals or specific institutional SOPs. To guarantee that your system includes the exact module configuration required for your research methodology and to align with your university’s procurement process or funding timeline, we highly encourage you to connect directly with our active sales management team or request a customized quote before purchase.