Agilent 7890B Gas Sampling Valve (GSV) GC System with TCD and FID
Zoom
PRODUCT INFORMATION
PRODUCT INFORMATION
✅ This Agilent 7890B GC with Gas Sampling Valve (GSV) System, TCD, and FID has been fully tested and refurbished at our in-house testing laboratory.
The Agilent 7890B Gas Sampling Valve (GSV) GC System with Thermal Conductivity Detection (TCD) and Flame Ionization Detection (FID) is a high-performance gas chromatography platform designed for the analysis of permanent gases, hydrocarbons, natural gas components, and volatile compounds in environmental, petrochemical, refinery, and industrial laboratories. The integrated gas sampling valve (GSV) system provides precise and reproducible gaseous sample introduction, while the TCD enables detection of permanent gases such as hydrogen, oxygen, nitrogen, carbon monoxide, and carbon dioxide, and the FID delivers highly sensitive hydrocarbon analysis for compounds such as methane, ethane, propane, and butanes. This Agilent Gas Sampling Valve GC also features advanced electronic pneumatic control (EPC), stable temperature programming, and reliable chromatographic reproducibility, making it well-suited for ASTM D1945 natural gas analysis, refinery gas monitoring, fuel gas testing, and industrial gas composition workflows requiring accurate, automated, and high-throughput gas chromatography performance.
At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent Gas Sampling Valve GC System with TCD and FID has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.
Included with Agilent 7890B GSV System with TCD and FID
Agilent 7890B GC System with TCD and FID Detectors
Heated valve oven assembly
(1) 10-port rotary valve
(1) 6-port rotary valve
(1) 6-port rotary valve
Complete manifold with stainless steel tubing
(3) pneumatic valve actuators with PTFE lines
Valve oven insulation and heater wiring
Stainless column fittings and capillary coil
Computer Workstation with Software
All Required Power and Connection Cables
Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.
Insights by AMPTIUS | AMP Tech Instruments
Precision Gas Sampling with Simultaneous TCD and FID Detection
If your laboratory requires a gas chromatograph specifically engineered for direct gas-phase sampling and the automated analysis of permanent gases and light hydrocarbons, the Agilent 7890B GC with Gas Sampling Valve (GSV), Thermal Conductivity Detector (TCD), and Flame Ionization Detector (FID) is an outstanding solution. Configured with 6-port and 10-port rotary gas sampling valves and dedicated sample loops for both TCD and FID analytical channels, the integrated Gas Sampling Valve (GSV) functions as a precision fixed-volume injection device. When connected directly to pressurized gas cylinders, process pipelines, or Tedlar® sample bags, it automatically captures and injects an identical gas volume into the GC column for every analysis, eliminating operator variability while maximizing injection accuracy and reproducibility. The Thermal Conductivity Detector (TCD) provides universal detection of permanent gases, including hydrogen, carbon dioxide, carbon monoxide, nitrogen, oxygen, and argon, while the Flame Ionization Detector (FID) simultaneously delivers exceptional sensitivity for light hydrocarbons such as methane, ethane, ethylene, propane, and butane. Purchasing an Amptius-certified refurbished Agilent 7890B GSV-TCD-FID system eliminates the substantial cost and lengthy lead times often associated with factory-customized gas analyzer configurations, allowing startups, industrial plants, energy producers, and third-party testing laboratories to deploy high-performance RGA/NGA capabilities immediately while significantly reducing capital investment.
Agilent 7890B Price and Cost of Ownership: Reliable Performance at Lower Cost
Certified refurbished systems commonly range from approximately $24,500 to $36,000. Laboratories seeking a comparable current-generation platform from Agilent can expect new Agilent 8890 Gas Chromatograph GSV Systems with TCD and FID to range from approximately $60,000 to $85,000. Beyond the initial purchase price, laboratories should consider ongoing ownership expenses such as carrier and detector gases, gas purification traps, analytical columns, septa, liners, calibration standards, valve maintenance, detector consumables, preventive maintenance, software support, replacement electronic components, and compliance-related qualification services for regulated workflows. Long-term operational considerations may also include gas sampling valve servicing, detector optimization, electronic pneumatic control (EPC) maintenance, and optional service contract coverage to maintain consistent chromatographic performance in high-throughput laboratory environments. Purchasing a certified refurbished Agilent 7890B GSV System with TCD and FID allows laboratories to significantly reduce capital investment while still achieving reliable dual-channel gas chromatography performance, analytical flexibility, and dependable long-term operation for regulated and industrial gas analysis applications.
Agilent 7890B GSV GC System with TCD and FID for GHG, NGA, and RGA Applications
The Agilent 7890B GC with Gas Sampling Valve (GSV), TCD, and FID delivers an all-in-one solution for Greenhouse Gas (GHG) tracking, Natural Gas Analysis (NGA), and Refinery Gas Analysis (RGA). Driven by integrated rotary gas sampling valves and precise Electronic Pneumatic Control (EPC), this platform automatically introduces fixed gas volumes directly into parallel analytical channels, ensuring maximum injection reproducibility with zero operator intervention. The dual-detector architecture pairs a universal Thermal Conductivity Detector (TCD) for measuring permanent gases like carbon dioxide, carbon monoxide, nitrogen, and hydrogen with a Flame Ionization Detector (FID) for high-sensitivity trace hydrocarbon quantification, including methane, ethane, and propane. This versatile setup easily handles complex gas streams, allowing energy producers and environmental labs to determine BTU heating values, certify fuel gas quality, and execute syngas or hydrogen characterizations in a single run. Built to meet established ASTM, GPA, and ISO industry standards, this system serves as an indispensable asset for petrochemical plants, contract testing labs, and environmental facilities seeking dependable, high-throughput gas analysis with low long-term operational costs.
AMP Tech Analytical Solutions for Academic Research and Grant-Funded Laboratories
At AMPTIUS | AMP Tech Instruments, we support the advancement of scientific education and innovation by providing cost-effective analytical instruments tailored to the unique budget constraints of the academic sector. Every pre-owned system in our inventory is independently evaluated and fully verified within our in-house testing laboratory, making our AMP Tech Certified equipment an ideal choice for university chemistry departments, core facilities, and researchers optimizing limited grant funding. Because academic applications vary heavily from undergraduate teaching labs to complex graduate research, we precisely document each unique listing to ensure the specific components align with your educational goals or specific institutional SOPs. To guarantee that your system includes the exact module configuration required for your research methodology and to align with your university’s procurement process or funding timeline, we highly encourage you to connect directly with our active sales management team or request a customized quote before purchase.
Related Products
WHAT ARE YOU LOOKING FOR?
MY CART (0)
Your shopping cart is empty.
MY ACCOUNT
SIGN UP
We're Here To Help!
Have a question? Need a quote? Want to schedule a free consultation? You can contact us at
Call Us: 844-AMP-TECH (267 8324) 1687 TIMOCUAN WAY SUITE 109, LONGWOOD, FL 32750