Hot

Agilent 7890A GC FID System with CTC Combipal Autosampler

Fully Tested and Refurbished

Warranty: Includes a 90-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Agilent 7890A GC FID System with CTC PAL Autosampler has been fully tested and refurbished at our in-house testing laboratory.

The Agilent 7890A GC-FID System with CTC Combipal Autosampler is a versatile gas chromatography system designed for reliable, high-throughput analysis of volatile and semi-volatile compounds. The 7890A GC provides precise temperature control and advanced electronic pneumatic control (EPC), ensuring excellent retention time stability and reproducible chromatographic performance. Equipped with a Flame Ionization Detector (FID), the system delivers sensitive and linear detection of hydrocarbons and organic compounds, making it ideal for applications involving fuels, solvents, and general organic analysis.

The CTC PAL CombiPAL Autosampler enhances the system with flexible, automated sample introduction capabilities, supporting liquid injection, headspace, and solid-phase microextraction (SPME). This multi-technique capability allows laboratories to handle diverse sample types while improving throughput and reducing manual variability. Commonly used in environmental testing, petrochemical analysis, food and flavor profiling, and pharmaceutical quality control, this configuration supports workflows aligned with methods such as EPA 8015, ASTM D2887, and USP <467> (when configured appropriately). Overall, the system is valued for its robustness, flexibility, and ability to adapt to a wide range of analytical applications.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent 7890A GC-FID System with CTC PAL Autosampler System has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Agilent 7890A GC FID CTC Combipal Autosampler System

  • Agilent 7890A GC
  • Single FID Flame Ionization Detector
  • Dual Inlet
  • CTC Combipal Autosampler
  • Headspace
  • Gameboy Controller
  • 2 Sample Trays
  • Wash Station
  • Computer Workstation with Operating Software
  • All Required Power and Communication Cables

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

Agilent 7890A GC FID System with CTC Combipal Autosampler: Applications in Pharma, Food, and Environmental Labs

The Agilent 7890A GC System with Flame Ionization Detector (FID) and CTC PAL CombiPAL Autosampler is widely used for gas chromatography analysis in environmental, petrochemical, pharmaceutical, food safety, chemical, forensic, and industrial laboratories. Common laboratory applications include nonhalogenated volatile organic compound (VOC) analysis, residual solvent testing aligned with USP <467>, hydrocarbon profiling, fuel and refinery gas analysis, fatty acid methyl ester (FAME) analysis, solvent purity testing, flavor and fragrance profiling, and petroleum contaminant monitoring. Environmental laboratories commonly utilize the system for hydrocarbon quantitation and nonhalogenated organic analysis in water, soil, and waste samples following workflows associated with EPA Method 8015, while petrochemical laboratories rely on it for fuel composition analysis and process gas monitoring. The Flame Ionization Detector provides highly sensitive and robust quantitation of hydrocarbons and organic compounds with wide linear dynamic range and dependable analytical reproducibility. The CTC PAL CombiPAL Autosampler enhances laboratory efficiency through automated liquid injection, headspace sampling, and solid-phase microextraction (SPME) workflow compatibility, improving sample throughput and reducing operator variability. Combined with stable chromatographic performance, low carryover, and dependable long-term operation, the Agilent 7890A GC FID System with CTC PAL CombiPAL Autosampler provides laboratories with efficient and reliable GC analysis for routine and high-throughput analytical applications.


Agilent 7890 GC FID Price and Cost of Ownership: Reliable Performance at Lower Cost

Certified refurbished systems typically range from approximately $24,000 to $28,000, offering substantial savings compared to comparable new-generation systems such as the Agilent 8890 GC paired with the PAL3 Series II Autosampler, which commonly range from approximately $68,000 to over $95,000 depending on configuration and automation options. In addition to acquisition costs, laboratories should consider ongoing operational expenses such as carrier gases, GC columns, septa, liners, syringes, autosampler consumables, detector maintenance, calibration standards, preventive maintenance, software support, and compliance-related qualification services for EPA, USP, ISO, and cGMP workflows. Long-term ownership considerations may also include injector maintenance, replacement electronic components, PAL autosampler servicing, and optional service contracts to maintain stable chromatographic performance and dependable analytical reproducibility in high-throughput laboratory environments. Purchasing a certified refurbished Agilent 7890A GC FID System with CTC PAL CombiPAL Autosampler allows laboratories to significantly reduce ownership costs while still benefiting from reliable FID quantitation, flexible automated sampling workflows, stable chromatographic performance, and proven long-term analytical reliability for routine and regulated laboratory applications.


EPA Method 8015: Nonhalogenated Organics Using the Agilent 7890A GC FID System with CTC PAL Autosampler

The Agilent 7890A GC System with Flame Ionization Detector (FID) and CTC PAL CombiPAL Autosampler provides a highly reliable and efficient analytical platform for laboratories performing EPA Method 8015 for the determination of nonhalogenated volatile and semivolatile organic compounds using GC/FID. This configuration delivers excellent chromatographic separation, robust hydrocarbon detection, and dependable quantitative reproducibility for petroleum hydrocarbons, gasoline range organics (GRO), diesel range organics (DRO), and other nonhalogenated organic compounds commonly analyzed in environmental water, soil, and waste samples. The Flame Ionization Detector offers high sensitivity, wide linear dynamic range, and stable response characteristics for hydrocarbon quantitation, making it well-suited for routine EPA Method 8015 workflows. The Agilent 7890A platform provides precise temperature control, low carryover, stable retention times, and reliable carrier gas management critical for consistent analytical performance, while the CTC PAL CombiPAL Autosampler enhances laboratory productivity through automated liquid injection, headspace sampling, and reproducible sample introduction. Combined with dependable chromatographic stability, flexible automation capabilities, and high-throughput workflow compatibility, the Agilent 7890A GC FID System with CTC PAL CombiPAL Autosampler provides laboratories with excellent analytical confidence and operational efficiency for EPA Method 8015 environmental testing applications.