Hot

Agilent 6890N with 5975 MSD Inert GCMS System

Fully Tested and Refurbished

Warranty: Includes a 180-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Agilent 6890N Gas Chromatograph with 5975 MSD Inert GCMS System has been fully tested and refurbished at our in-house testing laboratory.

The Agilent Technologies 6890N GC with 5975 MSD Inert GCMS System is a reliable and widely used analytical system designed for the identification and quantification of volatile and semi-volatile compounds in complex matrices. The Agilent 6890N GC provides stable oven temperature control and precise electronic pneumatic control (EPC), ensuring consistent chromatographic performance and reproducible results. The 5975 Inert MSD features an inert ion source and flow path that improve performance for active compounds, delivering strong sensitivity and dependable mass spectral identification. This configuration is widely used in environmental testing, pharmaceutical analysis, food safety, and forensic laboratories, supporting workflows aligned with EPA Method 8270 for direct-injection SVOC applications, as well as USP and AOAC applications requiring robust GC-MS analysis.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent Technologies 6890N Network GC System with 5975 MSD Inert GCMS System has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Agilent 6890N 5975 Inert GCMS System

  • Agilent 5975 Inert MSD with Turbo Pump
  • Agilent 6890N Network GC Gas Chromatograph with S/SL Inlet
  • Computer Workstation with Software
  • Rough Pump
  • All Required Power and Communication Cables
  • Extended Warranty Available and Quoted Upon Request

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

High-Sensitivity Gas Chromatography-Mass Spectrometry for Trace-Level Analysis

If your laboratory is struggling with active site adsorption or losing polar target compounds during trace-level organic screening, the Agilent 6890N GC with the 5975 Inert MSD delivers the enhanced surface inertness and sensitivity your workflow demands. By combining the precise Electronic Pneumatic Control (EPC) of the Agilent 6890N gas chromatograph with a highly advanced inert ion source, this platform minimizes chemical interactions along the flow path to maximize compound recovery and baseline stability. The single quadrupole mass analyzer operates flexibly in both full scan and Selected Ion Monitoring (SIM) modes, ensuring rapid spectral library matching and low detection limits for volatile and semi-volatile compounds (VOCs/SVOCs). It is a highly robust, cost-effective workhorse perfectly optimized for environmental laboratories running high-throughput EPA methods, petrochemical facilities monitoring purity, and pharmaceutical operations conducting rigorous residual solvent testing and impurity profiling.


Agilent 6890N 5975 MSD Inert GCMS System Price and Cost of Ownership: Reliable Performance at Lower Cost

The Agilent 6890N GC System with an Agilent 5975 Inert Mass Selective Detector offers an excellent balance of performance, versatility, and affordability for laboratories performing environmental, pharmaceutical, food safety, petrochemical, forensic, and industrial analyses. Certified refurbished systems typically range from approximately $19,000 to $25,000, providing substantial savings compared to comparable new platforms such as the Agilent 8890 GC with a 5977C Inert Plus MSD, which commonly range from approximately $75,000 to $115,000 or more depending on configuration, software, and sample introduction options. Beyond the initial acquisition cost, laboratories should budget for ongoing operational expenses, including carrier gases, GC columns, inlet liners, septa, calibration standards, rough pump maintenance, ion source cleaning, replacement filaments, vacuum system servicing, software support, preventive maintenance, and compliance-related qualification services. Long-term ownership costs remain manageable due to the proven reliability of the 6890N/5975 platform, widespread availability of replacement parts, and extensive industry service expertise. Additionally, the system can be configured with optional sample introduction technologies such as liquid autosamplers, headspace samplers, purge-and-trap concentrators, thermal desorption units, and SPME accessories, allowing laboratories to expand analytical capabilities as workflow requirements evolve. Purchasing a certified refurbished Agilent 6890N 5975 Inert GCMS System enables laboratories to significantly reduce capital expenditures while maintaining access to reliable mass spectral identification, enhanced inertness for active compounds, robust quantitative performance, and broad application flexibility, delivering exceptional long-term value for routine and advanced GC-MS testing workflows.


EPA Method 8270E: Semivolatile Organic Compounds Using the 6890N Agilent GC with 5975 MSD Inert GCMS System

The Agilent 6890N GC System with a 5975 Inert Mass Selective Detector provides a highly effective platform for EPA Method 8270, which is widely used for the determination of semivolatile organic compounds (SVOCs) in environmental samples. The system delivers reliable chromatographic separation and sensitive mass spectral detection for a broad range of analytes, including polycyclic aromatic hydrocarbons (PAHs), phenols, phthalates, nitroaromatics, chlorinated hydrocarbons, and other priority pollutants commonly encountered in soil, groundwater, wastewater, sediment, and hazardous waste matrices. The 5975 Inert MSD offers enhanced inertness that helps minimize analyte adsorption, improving quantitative accuracy and reproducibility for active and trace-level compounds. Laboratories benefit from robust compound identification through mass spectral library matching, excellent retention time stability, and dependable quantitative performance across complex environmental matrices. When integrated with automated liquid sampling systems such as the Agilent 7683 or 7693 Automatic Liquid Sampler, the platform supports efficient high-throughput workflows and consistent sample introduction for routine regulatory testing. Combined with proven Agilent reliability, strong sensitivity for semivolatile organic compounds, and broad applicability across environmental monitoring programs, the Agilent 6890N 5975 Inert GCMS System provides a powerful solution for EPA Method 8270 compliance testing, contaminant characterization, and environmental laboratory operations.


AMP Tech Analytical Solutions for Academic Research and Grant-Funded Laboratories

At AMPTIUS | AMP Tech Instruments, we support the advancement of scientific education and innovation by providing cost-effective analytical instruments tailored to the unique budget constraints of the academic sector. Every pre-owned system in our inventory is independently evaluated and fully verified within our in-house testing laboratory, making our AMP Tech Certified equipment an ideal choice for university chemistry departments, core facilities, and researchers optimizing limited grant funding. Because academic applications vary heavily from undergraduate teaching labs to complex graduate research, we precisely document each unique listing to ensure the specific components align with your educational goals or specific institutional SOPs. To guarantee that your system includes the exact module configuration required for your research methodology and to align with your university’s procurement process or funding timeline, we highly encourage you to connect directly with our active sales management team or request a customized quote before purchase.