Hot
Hot

Agilent 6890N 5975 Inert GCMS System

$22,500.00$19,000.00

You Save: $3,500.00 (16%)

Fully Tested and Refurbished

Warranty: Includes a 90-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders



American Express
Apple Pay
Diners Club
Discover
Google Pay
Mastercard
Shop Pay
Visa
PRODUCT INFORMATION
Additional Information
PRODUCT INFORMATION

✅ Put your trust in our Agilent 6890N 5975 GCMS System, thoroughly refurbrished, tested, and set up for immediate use in your lab. Our certification process ensures that the system performs at the manufacturer's specifications, and we back this up with comprehensive customer support and a 90-day parts labor warranty.

Our team recently acquired the Agilent 6890N 5975 Inert GCMS System in excellent working condition. The unit had been well-maintained and was fully operational when received. Upon arrival at our Central Florida facility, our skilled technicians thoroughly inspected and tested the system to ensure it met AMPTIUS quality standards. This Agilent system was then refurbished with only OEM (Original Agilent Technologies) parts to guarantee dependable performance. After the refurbishment, the GCMS system underwent Operational and Performance Qualification (OP/OQ) testing in our on-site certification laboratory. Upon passing all stringent quality checks, the system was AMPTIUS Certified and is now available for sale with warranty, giving you confidence and peace of mind in its performance.

The Agilent 6890N 5975 Inert GCMS System is an advanced analytical platform for the detection and identification of volatile compounds in complex samples. By combining gas chromatography (GC) with mass spectrometry (MS), it provides accurate, reproducible results in applications such as environmental analysis, forensics, pharmaceuticals, and chemical research. Featuring an inert ion source and low background noise, this system is perfectly suited for applications that demand precision and sensitivity. It is trusted by laboratories worldwide for its dependable performance, ease of operation, and versatility.

Agilent Technologies is a global leader in laboratory instruments, providing advanced solutions for life sciences, diagnostics, and applied chemical analysis. Known for its innovative technologies, Agilent's products are trusted by researchers and scientists worldwide for their accuracy, reliability, and cutting-edge performance.

Since 2002, our founder Mr. Perez has been dedicated to providing high-quality, reliable analytical instruments at affordable prices, helping reduce the cost of scientific discovery. At AMPTIUS, we specialize in buying, repairing, refurbishing, and certifying laboratory equipment, with a state-of-the-art facility in Central Florida that supports international shipments of certified, warrantied instruments.

Included with Agilent 6890N 5975 Inert GCMS System

  • Agilent 5975 Inert MSD w/ Turbo Pump
  • Agilent 6890N Network GC Gas Chromatograph w/ S/SL Inlet
  • Computer Workstation w/ Software
  • Rough Pump

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Additional Information

AMP Tech Instruments is committed to providing exceptional service and peace of mind. Please click any of the links below to learn more about our shipping, processes and policies.

Packaging & Shipping

Warranty Policies

Return Policies

Certification Process

Insights by AMPTIUS | AMP Tech Instruments

Price and cost of ownership of Agilent 6890N 5975 Inert GCMS System

The Agilent 6890N 5975 Inert GC/MS System is a reliable, high-performance solution for laboratories conducting routine and trace-level analysis of volatile and semi-volatile compounds. With a new system costing around $50,000 and refurbished units available for approximately $25,000, it offers excellent value for labs seeking dependable GC-MS performance on a budget. The 6890N GC is renowned for its precision, stability, and ease of integration, while the 5975 Inert MSD adds enhanced sensitivity and chemical inertness—ideal for reactive or complex sample matrices. This system is widely used across industries including environmental testing, forensics, food safety, and academic research. Ongoing costs include consumables such as GC columns, filaments, ion source parts, liners, and septa, along with carrier gases like helium or hydrogen. Maintenance of the MSD (cleaning the ion source, vacuum pump upkeep) is essential to ensure consistent results. A refurbished Agilent 6890N 5975 Inert GC/MS system, when properly tested and certified, can deliver years of reliable performance with a significantly reduced capital outlay—making it a smart choice for growing labs that need solid analytical capability without the high price tag.


Manual Injection to Full Automation: The Expandable Agilent 6890N 5975 GC/MS

The Agilent 6890N 5975 Inert GC/MS System is a dependable setup for identifying and measuring chemicals in laboratory samples. It includes the 6890N Gas Chromatograph with a standard split/splitless inlet, the 5975 Inert Mass Selective Detector with an inert ion source for improved detection of reactive or labile compounds, a computer workstation with software, and a rough pump. While this system does not include an autosampler, it is fully functional for manual injection workflows and offers convenient upgrade options for enhanced automation. Laboratories can expand its capabilities by adding compatible sample introduction systems, such as the Agilent 7683 or 7693 autosamplers, a purge and trap unit for VOC testing, or a headspace sampler for volatile solvent analysis. This configuration serves as a strong foundation for accurate chemical analysis in environmental, pharmaceutical, petrochemical, and food testing laboratories. The Agilent 6890N 5975 GC/MS System is compatible with a variety of EPA and ASTM methods depending on configuration. It can be configured to support EPA Method TO-15 when used with an appropriate preconcentration system for canister-based air samples. When paired with a purge and trap concentrator, the system also supports EPA Method 502.2 for detecting VOCs in drinking water. Although ASTM D5501 is traditionally performed using a GC-FID for quantifying ethanol and methanol in fuel-grade ethanol, some laboratories may choose to apply GC/MS as a supplemental tool for additional compound confirmation or non-standard workflows. Overall, the system’s flexibility and reliable performance make it a trusted platform for regulated chemical analysis across multiple industries."