Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Autosampler
Zoom
PRODUCT INFORMATION
PRODUCT INFORMATION
✅ This Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Autosampler has been fully tested and refurbished at our in-house testing laboratory.
The Agilent 7890B GC with 7010B Triple Quadrupole (GC/MS/MS) System and 7693 Autosampler is a high-performance analytical platform designed for ultra-sensitive and selective analysis of trace-level compounds in complex matrices. The 7890B GC provides precise temperature control and advanced electronic pneumatic control (EPC), ensuring excellent chromatographic reproducibility, while the 7010B triple quadrupole mass spectrometer enables highly specific quantitative analysis using tandem MS (MS/MS) with superior sensitivity and low detection limits. The integrated 7693 Autosampler delivers precise, repeatable automated injections and supports high-throughput batch processing, improving productivity and minimizing variability. This configuration is widely used in environmental testing, food safety, pharmaceutical analysis, and forensic laboratories, supporting workflows aligned with EPA, AOAC, and regulatory methods where GC-MS/MS is required for confirmatory analysis of pesticides, SVOCs, and other trace contaminants.
At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Autosampler has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.
Included with Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Autosampler
Agilent G7013B 7010B Triple Quadrupole MS/MS
Agilent G3440B 7890B GC Gas Chromatograph
Agilent G4514A 7693 Autosampler Tray with 150 Vial Tray with three removable (50-Vial) Racks
Agilent G4513A 7693 Autosampler Injector Tower
Foreline Pump
Computer Workstation with Masshunter Software and Nist Libraries
All Required Power and Communication Cables
Extended Warranty Available and Quoted Upon Request
Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.
Insights by AMPTIUS | AMP Tech Instruments
Ultra-Trace Quantitative Analysis for Advanced Analytical Laboratories
If your laboratory is looking to eliminate matrix interference and maximize sub-femtogram detection precision during complex ultra-trace quantification applications, the Agilent 7890B Gas Chromatograph / 7010B Triple Quadrupole GC MS System paired with a 7693 Automatic Liquid Sampler (ALS) delivers the ultimate intelligent, automated solution. Featuring an advanced High Efficiency Source (HES) and multiple reaction monitoring (MRM) acquisition, the high-performance system works alongside electronic pneumatic control (EPC) and a precision programmable oven to guarantee flawless compound confirmation and exceptional sensitivity across a wide range of volatile and semi-volatile compound analyses. The integrated 7693 ALS further streamlines your workflow by automating highly reproducible liquid injections, completely removing background noise and manual sample handling restrictions prior to tandem mass spectrometry detection. It is a premier, robust powerhouse for food and beverage facilities tracking pesticide residues and contaminants, as well as pharmaceutical operations requiring uncompromised reproducibility and data integrity for strict nitrosamine analysis, impurity profiling, and residual solvent testing.
Agilent 7890B 7010B GC-MS/MS System Price and Cost of Ownership: Reliable Performance at Lower Cost
The total cost of ownership for the Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Autosampler includes the initial acquisition cost as well as ongoing expenses for preventive maintenance, turbomolecular and roughing pump servicing, ion source cleaning, column and inlet consumables, autosampler maintenance, calibration, and routine performance verification. A certified refurbished Agilent 7890B/7010B GC-MS/MS system with a 7693 Autosampler typically ranges from $115,000 to $150,000, offering substantial savings compared to a new Agilent 8890 GC with 7010C Triple Quadrupole GC/MS and 7693A Autosampler, which generally costs between $195,000 and $245,000. For laboratories requiring highly sensitive GC-MS/MS analysis without the premium cost of a new platform, a professionally refurbished system offers exceptional value by delivering reliable triple-quadrupole performance, automated sample handling, and robust analytical capabilities. When purchased from a reputable supplier with comprehensive testing, certification, and warranty coverage, a refurbished Agilent 7890B/7010B GC TQ System offers a cost-effective solution for high-throughput pharmaceutical, environmental, food safety, forensic, and regulatory testing laboratories while maintaining the performance and reliability expected from Agilent instrumentation.
EPA Method 8270E (Appendix B): Semivolatile Organic Compounds (SVOCs) Using the Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Autosampler
The Agilent 7890B 7010B Triple Quadrupole GC TQ System with 7693 Automatic Liquid Sampler is a highly effective platform for EPA Method 8270E (Appendix B): Semivolatile Organic Compounds (SVOCs), delivering the sensitivity, selectivity, and robustness required for complex environmental analyses. The 7010B Triple Quadrupole GC/MS utilizes advanced multiple reaction monitoring (MRM) to minimize matrix interferences and improve the identification and quantitation of target SVOCs in challenging sample matrices such as soil, sediment, wastewater, and industrial extracts. The 7890B GC provides excellent chromatographic separation, precise electronic pneumatic control, and stable retention time performance to ensure consistent analysis across a broad range of semivolatile compounds. The 7693 Automatic Liquid Sampler enhances analytical reproducibility through accurate, automated sample introduction while supporting high-throughput laboratory workflows. Combined with exceptional trace-level sensitivity, reliable quantitative performance, and proven Agilent reliability, the Agilent 7890B/7010B GC TQ System with 7693 Autosampler provides an ideal solution for EPA 8270E compliance testing, environmental monitoring, remediation studies, and regulatory laboratory applications.
AMP Tech Analytical Solutions for Academic Research and Grant-Funded Laboratories
At AMPTIUS | AMP Tech Instruments, we support the advancement of scientific education and innovation by providing cost-effective analytical instruments tailored to the unique budget constraints of the academic sector. Every pre-owned system in our inventory is independently evaluated and fully verified within our in-house testing laboratory, making our AMP Tech Certified equipment an ideal choice for university chemistry departments, core facilities, and researchers optimizing limited grant funding. Because academic applications vary heavily from undergraduate teaching labs to complex graduate research, we precisely document each unique listing to ensure the specific components align with your educational goals or specific institutional SOPs. To guarantee that your system includes the exact module configuration required for your research methodology and to align with your university’s procurement process or funding timeline, we highly encourage you to connect directly with our active sales management team or request a customized quote before purchase.
Related Products
WHAT ARE YOU LOOKING FOR?
MY CART (0)
Your shopping cart is empty.
MY ACCOUNT
SIGN UP
We're Here To Help!
Have a question? Need a quote? Want to schedule a free consultation? You can contact us at
Call Us: 844-AMP-TECH (267 8324) 1687 TIMOCUAN WAY SUITE 109, LONGWOOD, FL 32750