Hot

Agilent 6890N GC with 5975 MSD and Tekmar Atomx XYZ | Purge and Trap GCMS System

Fully Tested and Refurbished

Warranty: Includes a 180-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Agilent 6890N Gas Chromatograph with 5975 MSD and Tekmar Atomx XYZ has been fully tested and refurbished at our in-house testing laboratory.

The Agilent 6890N GC with 5975 Mass Selective Detector (GC/MS) and Tekmar Atomx XYZ Purge & Trap System is a powerful analytical platform designed for the detection and quantification of volatile organic compounds (VOCs) in complex matrices such as water and soil. The Agilent 6890N GC provides stable temperature control and precise electronic pneumatic control (EPC) for consistent chromatographic performance, while the 5975 MSD delivers reliable mass spectral identification and quantification. The Tekmar Atomx XYZ Purge & Trap system automates sample extraction by purging VOCs from liquid samples onto a trap for thermal desorption into the GC, improving sensitivity and minimizing matrix interference. This configuration is widely used in environmental testing laboratories, supporting workflows aligned with EPA methods such as 524.2, 524.3, and 8260, where purge-and-trap GC-MS is required for accurate VOC analysis.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent Technologies 6890N with 5975 MSD and Tekmar Atomx XYZ has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Agilent 6890N 5975 GC/MS System with Tekmar Atomx XYZ Trap & Purge

  • Agilent 6890N Network GC Gas Chromatograph
  • Agilent 5975 Mass Spectrometer with Turbo Pump
  • Teledyne Tekmar Atomx XYZ
  • Rough Pump
  • Computer Workstation with Software
  • All Required Power and Communication Cables
  • Extended Warranty Available and Quoted Upon Request

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

Automated Trace-Level VOC Analysis for Environmental and Industrial Laboratories

If your laboratory is struggling with manual extraction errors or failing to meet strict trace-level detection limits for volatile organic compounds (VOCs), the Agilent 6890N/5975 GC/MS system paired with a Tekmar Atomx XYZ Purge and Trap system delivers the ultimate automated, high-sensitivity solution. By combining the precise Electronic Pneumatic Control (EPC) of the Agilent 6890N gas chromatograph with the reliable 5975 single quadrupole MSD, this platform achieves exceptional peak resolution and rapid spectral library matching in full scan or SIM modes. The integrated Tekmar Atomx XYZ concentrator features a multi-axis robotic autosampler that completely automates sample extraction, moisture management, and trap desorption, maximizing the recovery of low-level volatiles while eliminating time-consuming manual prep. It is a rugged, highly cost-effective powerhouse perfectly optimized for environmental laboratories running high-throughput water and soil analysis under strict regulatory compliance, including EPA Methods 8260 and 524.


Agilent 6890N 5975 Purge and Trap GCMS System Price and Cost of Ownership: Reliable Performance at Lower Cost

Certified refurbished systems typically range from approximately $46,500 to $55,000, offering significant savings compared to comparable new platforms such as an Agilent 8890B GC with a 5977C MSD and Teledyne Tekmar Atomx XLR Purge & Trap system, which commonly range from approximately $101,000 to $126,000 depending on configuration, software, and automation options. Beyond the initial acquisition cost, laboratories should budget for ongoing operational expenses, including carrier and purge gases, GC columns, purge-and-trap consumables, sample vials, calibration standards, vacuum pump maintenance, ion source cleaning, trap maintenance, replacement filaments, software support, preventive maintenance, and compliance-related qualification services. Long-term ownership considerations may also include detector servicing, vacuum system upkeep, performance verification, and periodic replacement of purge-and-trap components to maintain analytical sensitivity and reliability. Purchasing a certified refurbished Agilent 6890N 5975 GC/MS System with Tekmar Atomx XYZ Trap & Purge allows laboratories to significantly reduce capital expenditures while benefiting from automated VOC preconcentration, sensitive mass spectral detection, reliable compound identification, robust quantitative performance, and proven compatibility with EPA drinking water and environmental methods such as EPA 524.2, EPA 524.3, and EPA 8260.


EPA Method 524.2 and 524.3: Measurement of Purgeable Organic Compounds in Water Using the Agilent Technologies 6890N Network GC System with 5975 MSD and Tekmar Atomx XYZ

The Agilent 6890N GC/MS System with an Agilent 5975 Mass Selective Detector and Tekmar Atomx XYZ Trap and Purge System provides a highly effective platform for EPA Methods 524.2 and 524.3, which are used for the determination of purgeable organic compounds in drinking water. The Tekmar Atomx XYZ automates purge-and-trap sample preparation and preconcentration, efficiently extracting volatile organic compounds (VOCs) from water samples while enhancing sensitivity and reducing manual sample handling. The Agilent 6890N GC delivers excellent chromatographic separation of target analytes, including aromatic hydrocarbons, chlorinated solvents, fuel oxygenates, and other regulated VOCs, while the 5975 MSD provides highly sensitive mass spectral identification and quantitation with reliable library matching capabilities. Environmental and municipal water laboratories benefit from low-level detection capabilities, excellent reproducibility, and robust analytical performance that support regulatory compliance and drinking water monitoring programs. The automated Atomx XYZ platform also improves laboratory throughput, minimizes operator variability, and streamlines routine VOC testing workflows. Combined with sensitive purge-and-trap concentration, dependable GC/MS performance, and proven reliability, the Agilent 6890N 5975 GC/MS System with Tekmar Atomx XYZ Trap & Purge provides a powerful solution for EPA 524.2 and EPA 524.3 drinking water VOC analysis applications.


AMP Tech Analytical Solutions for Academic Research and Grant-Funded Laboratories

At AMPTIUS | AMP Tech Instruments, we support the advancement of scientific education and innovation by providing cost-effective analytical instruments tailored to the unique budget constraints of the academic sector. Every pre-owned system in our inventory is independently evaluated and fully verified within our in-house testing laboratory, making our AMP Tech Certified equipment an ideal choice for university chemistry departments, core facilities, and researchers optimizing limited grant funding. Because academic applications vary heavily from undergraduate teaching labs to complex graduate research, we precisely document each unique listing to ensure the specific components align with your educational goals or specific institutional SOPs. To guarantee that your system includes the exact module configuration required for your research methodology and to align with your university’s procurement process or funding timeline, we highly encourage you to connect directly with our active sales management team or request a customized quote before purchase.