Perkin Elmer Optima 8300 Continuous ICP-OES System

Fully Tested and Refurbished

Warranty: Includes a 90-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Perkin Elmer Optima 8300 Continuous ICP-OES System has been fully tested and refurbished at our in-house testing laboratory.

The PerkinElmer Optima 8300 ICP-OES System is a high-performance elemental analysis platform designed for fast, accurate multi-element detection in a wide range of sample types. It uses a high-temperature inductively coupled plasma (ICP) source to excite atoms and measure element-specific emission wavelengths, delivering strong sensitivity, wide dynamic range, and excellent analytical precision. The system features a dual-view (axial and radial) configuration, allowing optimized performance for both trace-level and high-concentration elements, while its simultaneous detection capability supports rapid, high-throughput analysis. Known for its robustness and reliability, the Optima 8300 is widely used in environmental testing, food and agriculture, pharmaceutical and chemical analysis, and industrial quality control, supporting workflows aligned with EPA, ASTM, AOAC, and USP methods for elemental analysis.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Perkin Elmer Optima 8300 Continuous ICP-OES System has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Perkin Elmer Optima 8300 Continuous ICP-OES System

  • Perkin Elmer Optima 8300 ICP-OES System
  • Computer Workstation with Operating Software
  • Chiller
  • On-Site Installation and Familiarization Available. Please Inquire for More Info
  • Optional Autosampler Addition available. Please Inquire
  • Extended Warranty Available and Quoted Upon Request

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

PerkinElmer Optima 8300 ICP-OES Applications in Environmental, Food, and Pharmaceutical Testing

The PerkinElmer Optima 8300 ICP-OES System is widely used for multi-element inorganic analysis in environmental, pharmaceutical, food safety, petrochemical, mining, agricultural, materials science, and industrial laboratories. Common laboratory applications include trace metals analysis in drinking water, wastewater, soil, sludge, and solid waste samples following workflows associated with EPA Methods 200.7, 6010, and related regulatory methods. Environmental laboratories frequently utilize the system for monitoring regulated elements such as arsenic, cadmium, chromium, copper, lead, nickel, selenium, and zinc, while pharmaceutical laboratories apply it to elemental impurity testing and raw material characterization in workflows aligned with USP <232> and USP <233>. Food and agricultural laboratories use the Optima 8300 for nutritional mineral analysis, contaminant screening, and fertilizer characterization, while industrial and mining laboratories rely on it for alloy analysis, process control, geological testing, and quality assurance applications. The system’s advanced optical design and simultaneous detection capabilities enable rapid multi-element measurements across a wide concentration range, supporting both trace-level and major element determinations. Combined with robust plasma performance, high sample throughput, excellent analytical reproducibility, and dependable long-term reliability, the PerkinElmer Optima 8300 ICP-OES System provides laboratories with an efficient and versatile platform for routine and high-throughput elemental analysis.


Perkin Elmer Optima 8300 ICP-OES System: Refurbished System Benefits and Pricing

The PerkinElmer Optima 8300 ICP-OES System provides a powerful and cost-effective solution for environmental, pharmaceutical, food safety, industrial, mining, and materials testing laboratories requiring high-throughput multi-element analysis. New systems typically range from approximately $98,000 to $117,000, depending on configuration, autosampler options, software packages, and accessories, while certified refurbished systems generally range from $30,000 to $38,000, offering substantial savings on initial capital investment. In addition to acquisition costs, laboratories should consider ongoing operational expenses such as argon gas consumption, sample introduction components, nebulizers, spray chambers, torch assemblies, pump tubing, calibration standards, preventive maintenance, software support, and compliance-related qualification services for EPA, USP, ISO, AOAC, and cGMP workflows. Long-term ownership considerations may also include RF generator maintenance, detector servicing, autosampler support, replacement electronic components, and optional service agreements to maintain analytical accuracy and dependable instrument uptime. Purchasing a certified refurbished PerkinElmer Optima 8300 ICP-OES System allows laboratories to significantly reduce ownership costs while still benefiting from rapid simultaneous multi-element analysis, robust plasma performance, excellent analytical reproducibility, and proven long-term reliability for routine and high-throughput elemental testing applications.


USP <232> and USP <233> Using Perkin Elmer Optima 8300 ICP-OES System

The PerkinElmer Optima 8300 ICP-OES System provides a robust and efficient platform for pharmaceutical laboratories performing elemental impurity testing in support of USP <232> (Elemental Impurities-Limits) and USP <233> (Elemental Impurities-Procedures). The system delivers rapid simultaneous multi-element analysis with excellent precision, wide dynamic range, and reliable analytical reproducibility, making it well-suited for the quantification of regulated elemental impurities in pharmaceutical ingredients, excipients, raw materials, and finished drug products. Its advanced optical design and stable plasma performance enable accurate measurement of elements such as arsenic, cadmium, chromium, copper, nickel, lead, and other specified impurities when method detection limits and target concentration ranges are appropriate for ICP-OES analysis. The Optima 8300 supports high-throughput pharmaceutical workflows through fast analysis times, automated sample handling compatibility, and dependable long-term instrument stability, helping laboratories improve productivity while maintaining data quality. Combined with strong matrix tolerance, efficient multi-element capability, and support for validated elemental impurity testing procedures, the PerkinElmer Optima 8300 ICP-OES System provides pharmaceutical laboratories with a reliable solution for USP <232> and USP <233> compliance workflows.