Hot

Perkin Elmer Spectrum Two FT-IR Spectrometer

Used (Pre-Owned)

Warranty: Includes a 90-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

This Perkin Elmer Spectrum Two FT-IR Spectrometer has been fully tested and refurbished at our in-house testing laboratory.

The PerkinElmer Spectrum Two FT-IR Spectrometer is a compact and versatile infrared spectroscopy system designed for reliable identification and characterization of organic, inorganic, and polymeric materials. It delivers high-quality spectral data across the mid-infrared range, enabling accurate qualitative and quantitative analysis for a wide variety of sample types. The system supports multiple sampling accessories, including ATR, transmission, and reflectance, allowing flexible analysis of solids, liquids, and powders with minimal sample preparation. Known for its ease of use, robust design, and intuitive software, the Spectrum Two is widely used in pharmaceutical quality control, chemical analysis, environmental testing, food safety, and academic research laboratories.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Perkin Elmer Spectrum Two FT-IR Spectrometer has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with PerkinElmer Spectrum Two FTIR Spectrometer

  • PerkinElmer Spectrum Two FTIR Spectrometer (Part Number: L1600300)
  • Standard Sample Stage and Holder
  • Lithium Tantalate (LiTa) Detector
  • Computer Workstation
  • Spectrum 10 Software (installed)
  • Sample Compartment Lid
  • All Necessary Cables for Operation
  • Extended Warranty Available & Quoted Upon Request

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

Perkin Elmer Spectrum Two FT-IR Spectrometer: Applications in Pharma, Food, and Environmental Labs

The PerkinElmer Spectrum Two FT-IR Spectrometer is widely used for rapid qualitative and quantitative infrared analysis in pharmaceutical, chemical, polymer, environmental, food, forensic, academic, and industrial laboratories. Common laboratory applications include raw material identification, pharmaceutical excipient verification, polymer characterization, contaminant analysis, reaction monitoring, and quality control testing in workflows aligned with USP <197>, EP 2.2.24, and cGMP analytical requirements. Environmental and industrial laboratories commonly utilize the system for lubricant analysis, biodiesel quantitation, microplastic identification, coating analysis, and chemical composition testing. In food and beverage laboratories, the Spectrum Two FT-IR supports additive verification, oil and fat characterization, packaging material analysis, and ingredient authentication workflows. Forensic and research laboratories frequently apply the system for unknown material identification, fiber analysis, counterfeit detection, and failure investigations. The compact FT-IR platform delivers high spectral resolution, rapid spectral acquisition, stable optical performance, and user-friendly operation, while optional ATR accessories enable direct analysis of solids, liquids, gels, and powders with minimal sample preparation. Combined with dependable long-term reproducibility and flexible application support, the PerkinElmer Spectrum Two FT-IR Spectrometer provides laboratories with efficient and reliable infrared analysis for routine and high-throughput analytical workflows.


Perkin Elmer Spectrum Two FT-IR Spectrometer: Reliable Performance at Lower Cost

The PerkinElmer Spectrum Two FT-IR Spectrometer provides a compact and cost-effective infrared spectroscopy solution for pharmaceutical, chemical, polymer, environmental, food, forensic, and industrial laboratories requiring rapid material identification and compositional analysis. New systems typically range from approximately $35,000 to $47,000, depending on accessory configuration, ATR options, software packages, and application modules, while certified pre-owned systems generally range from $13,000 to $21,000, offering substantial savings on initial capital investment. In addition to acquisition costs, laboratories should consider ongoing operational expenses such as ATR crystal maintenance, desiccant replacement, validation standards, software licensing, preventive maintenance, optical alignment checks, and compliance-related qualification support for USP <197>, EP 2.2.24, ISO, and cGMP workflows. Long-term ownership considerations may also include detector servicing, replacement electronic components, environmental control for optimal optical stability, and optional service contracts to maintain dependable spectral performance and analytical reproducibility. Purchasing a certified pre-owned PerkinElmer Spectrum Two FT-IR Spectrometer allows laboratories to significantly reduce ownership costs while still benefiting from rapid spectral acquisition, minimal sample preparation, reliable long-term operation, and proven analytical performance for routine and high-throughput FTIR applications.


ASTM D7066 Using Perkin Elmer Spectrum Two FT-IR Spectrometer

The PerkinElmer Spectrum Two FT-IR Spectrometer provides a highly effective and forward-looking solution for laboratories performing ASTM D7066 for the determination of recoverable oil and grease and nonpolar material by infrared analysis. The system delivers high spectral resolution, stable optical performance, and dependable quantitative accuracy for measuring hydrocarbons, oils, greases, and nonpolar contaminants in environmental water and wastewater samples. For laboratory managers seeking to reduce dependence on chlorotrifluoroethylene solvent (S-316), the Spectrum Two offers significant operational and regulatory advantages by also supporting alternative ASTM and EPA infrared workflows that utilize cyclohexane extraction combined with Horizontal Attenuated Total Reflection (HATR) analysis. In these methods, the cyclohexane solvent is evaporated directly from the HATR crystal surface prior to infrared measurement, allowing laboratories to bypass the use of restricted ozone-depleting solvents entirely while simplifying solvent handling and reducing hazardous material concerns. The compact design, rapid spectral acquisition, low maintenance requirements, and dependable analytical reproducibility of the Spectrum Two make it well suited for high-throughput environmental laboratories transitioning toward safer and more sustainable oil and grease analysis workflows. Combined with reliable long-term performance and flexible FTIR method compatibility, the PerkinElmer Spectrum Two FT-IR Spectrometer provides laboratories with a cost-effective platform for modern environmental compliance testing and solvent reduction initiatives.