Hot

Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler

Fully Tested and Refurbished

Warranty: Includes a 90-Day warranty

International Shipping: Shipping to Anywhere in the World for International Orders

PRODUCT INFORMATION
PRODUCT INFORMATION

✅ This Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler has been fully tested and refurbished at our in-house testing laboratory.

The Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler is a high-performance elemental analysis system designed for accurate and efficient multi-element detection in a wide range of sample types. The Agilent 5110 ICP-OES utilizes a high-temperature argon plasma to excite atoms, measuring element-specific emission wavelengths to determine concentrations with strong sensitivity and a wide dynamic range. In the VDV (Vertical Dual View) configuration, the system collects axial and radial measurements sequentially, allowing optimized performance across both trace and high-concentration elements. The integrated Agilent SPS 4 Autosampler enhances throughput by automating sample introduction, improving reproducibility, and reducing manual handling. This configuration is widely used in environmental testing, food and agriculture, pharmaceutical and chemical analysis, and industrial quality control, supporting workflows aligned with EPA, ASTM, AOAC, and USP methods for elemental analysis.

At AMPTIUS | AMP Tech Instruments, we supply high-quality analytical systems engineered to meet the demands of modern laboratories. This Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler has been expertly refurbished and includes warranty coverage for added peace of mind. Our application scientists are ready to provide professional technical guidance to help you integrate the system efficiently and maintain reliable analytical performance.

Included with Agilent 5110 Vertical Dual View (VDV) ICP-OES (G8015A)

  • Agilent 5110 Vertical Dual View (VDV) ICP-OES (G8015A) MFG. 2017
  • Agilent SPS 4 Autosampler
  • Sample Introduction (Purge Windows, Nebulizer, Torch, Spray Chamber and Pump Tubing)
  • Recirculating Chiller
  • Computer Workstation with Software
  • All Required Power and Communication Cables

Disclaimer: Unless otherwise stated the seller is not authorized by or associated with the original equipment manufacturer. This product has not been reviewed by the manufacturer to reverify its quality or compatibility with its other products.

Insights by AMPTIUS | AMP Tech Instruments

Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler: Applications in Pharma, Food, and Environmental Labs

The Agilent 5110 ICP-OES with Vertical Dual View (VDV) configuration and Agilent SPS 4 Autosampler is widely used for multi-element analysis in environmental, pharmaceutical, food safety, petrochemical, mining, agricultural, and industrial laboratories. Common laboratory applications include trace metals analysis in drinking water and wastewater following EPA Method 200.7, elemental impurity testing aligned with USP <232> and USP <233>, soil and sediment metals analysis, fertilizer and agricultural nutrient testing, food and beverage elemental screening, mining and geological analysis, lubricant and wear metal testing, and chemical manufacturing quality control workflows. Environmental laboratories commonly use the system for monitoring arsenic, lead, cadmium, chromium, copper, zinc, and other regulated elements in water and waste samples, while pharmaceutical and industrial laboratories rely on it for routine elemental quantitation and process validation. The Vertical Dual View (VDV) configuration enables both axial and radial plasma viewing for improved analytical flexibility across high and low concentration ranges, while the SPS 4 Autosampler enhances laboratory throughput through automated sample handling and reproducible sample introduction. Combined with stable plasma performance, low argon consumption, reliable multi-element detection, and dependable chromatographic reproducibility, this configuration provides accurate and efficient ICP-OES analysis for routine and high-throughput laboratory applications.


Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler: Refurbished System Benefits and Pricing

The Agilent 5110 ICP-OES with Vertical Dual View (VDV) configuration and the Agilent SPS 4 Autosampler provide a high-performance and cost-effective solution for laboratories requiring fast multi-element analysis in environmental, pharmaceutical, food safety, mining, petrochemical, and industrial applications. New systems typically range from approximately $110,000 to over $145,000, depending on detector configuration, sample introduction components, software packages, and automation options, while certified refurbished systems generally range from $42,000 to $70,000, offering substantial savings on initial capital investment. In addition to acquisition costs, laboratories should consider ongoing operational expenses such as argon gas consumption, torch and nebulizer replacements, pump tubing, standards and calibration solutions, autosampler consumables, preventive maintenance, software licensing, detector servicing, and compliance-related qualification support for EPA, USP, ISO, and cGMP workflows. Long-term ownership considerations may also include plasma component maintenance, SPS 4 Autosampler servicing, replacement electronic components, and optional service contracts to maintain stable plasma performance and dependable analytical reproducibility in high-throughput laboratory environments. Purchasing a certified refurbished Agilent 5110 VDV ICP-OES with SPS 4 Autosampler allows laboratories to significantly reduce ownership costs while still benefiting from reliable simultaneous multi-element analysis, automated sample handling, low argon consumption, and proven long-term analytical performance for regulated and research-based laboratory applications.


EPA Method 200.7: Determination of Metals and Trace Elements Using Agilent 5110 VDV ICP-OES with Agilent SPS 4 Autosampler

The Agilent 5110 ICP-OES with Vertical Dual View (VDV) configuration and the Agilent SPS 4 Autosampler provide a highly efficient and reliable platform for laboratories performing EPA Method 200.7 for the determination of metals and trace elements in water and waste samples. This configuration delivers fast simultaneous multi-element analysis with excellent sensitivity, wide dynamic range, and dependable analytical reproducibility for regulated environmental testing workflows. The VDV technology enables both axial and radial plasma viewing, allowing laboratories to accurately quantify trace-level and higher concentration elements within the same analytical run while improving analytical flexibility and reducing sample reruns. The Agilent 5110 platform also offers stable plasma performance, low argon consumption, and rapid sample throughput, making it well-suited for high-volume environmental laboratories analyzing drinking water, wastewater, groundwater, and industrial waste samples. The integrated SPS 4 Autosampler further enhances workflow efficiency through automated sample handling and reproducible sample introduction, helping laboratories improve throughput, reduce operator variability, and maintain consistent EPA Method 200.7 analytical performance for metals such as arsenic, lead, cadmium, chromium, copper, and zinc.